0-9
A
- ACCELERATOR
- Chemicals that are used as a catalyst which accelerate the process of turning liquid latex into a gel form. These additional chemicals, which are added in during the manufacturing of latex gloves, are added mainly for elasticity and durability.
- ADSORPTION
- The process of an adsorbate (molecules, biomolecules, ions, or atoms) adhering to and accumulating on the surface of a substance. The adsorbent can be a liquid, gas, or a solid with dissolved surface molecules.
- ALLERGEN
- A substance, usually a protein, that is able to elicit an IgE antibody response and activate mast cells. Every allergen is an antigen but not every antigen is an allergen.
- ALLERGIC CONTACT DERMATITIS
- An allergic rash (Type IV) with physiological memory to the chemical sensitizer that caused it. This means that it will cause the allergic rash again with subsequent exposure.
- AMBIDEXTROUS
- Can be used on either the left or right.
- AMMONIA
- Ammonia is a preservative and stabilizer in latex concentrate.
- AQL
- Acceptable Quality Limit, is a quality specification that all glove manufacturers use to specify the pinhole rate in surgical and examination gloves. The FDA specifies an AQL of 1.5 for surgical gloves and 2.5 for examination gloves. An AQL of 2.5 means the defect level from a large sampling of gloves will not be more than 2.5%. The EU, via the EN455 series of standards, requires that both examination and surgical gloves meet AQL 1.5
- ASTM (American Society of Testing and Materials)
- Organized in 1898, The ASTM is a not-for-profit organization that provides a forum for the development and publication of voluntary standards for materials, products, systems and services in various industries. The
FDA uses some of the standards and specifications developed by the ASTM to establish its requirements for examination gloves.
- ASTM D3577 – Standard Specification for Rubber Surgical Gloves
- This specifies dimensions, tolerances and physical requirements for latex surgical gloves.
- ASTM D3578 – Standard Specification of Rubber Examination Gloves
- This specifies dimensions, tolerances and physical requirements for latex examination gloves.
- ASTM D5151 – Standard Test Method for the Detection of Holes in Medical Gloves
- This test method covers the detection of holes that allow water leakage under conditions described in the test.
- ASTM D5712-95 – Analysis of Protein in Natural Rubber and its Products
- An analytical test method to determine the amount of extractable protein associated with natural rubber and its products. All protein labelled latex gloves may only contain a maximum of 50 micrograms of protein per gram of glove when tested.
- ASTM D6124 – STANDARD TEST METHOD FOR RESIDUAL POWDER ON MEDICAL GLOVES
- This test method determines the average powder or filter retained mass found on a sample of medical gloves as described in the test. The target amount of powder per powdered glove is 120mg and powder free gloves may only contain a maximum of 2.0mg powder per glove.
B
- B GRADE
- Also known as industrial grade gloves, for non-medical use. These gloves are either made to not meet medical glove standards in the first place, or they fail in pinhole rates or specifications in quality control, and are downgraded from medical grade to B grade. These gloves are usually labelled as disposable gloves and cannot be labelled as exam gloves.
- BEADED CUFF
- A rolled or “bead” at the open end of a glove. The beading increases the glove strength when donning and effectively
adds protection against any fluid drips.
- BLOOD-BORNE PATHOGENS
- Infectious organisms in the blood, of which the predominant medical interest is their contamination of gloves, etc. all of which health workers are exposed to.
- BREAK THROUGH TIME
- The time elapsed between the initial chemical reaction and the detection of the chemical inside the glove.
C
- CALCIUM CARBONATE
- A mould-release agent added in the beginning of the production cycle to help the release of gloves from the hand moulds or formers. Calcium carbonate is a naturally occurring substance found in chalk, limestone and sea shells.
- CAUTION STATEMENT
- This is an FDA requirement for Natural Rubber Latex (NRL) glove products which must state that “This Product
Contains Natural Rubber Latex Which May Cause Allergic Reactions.” Within the EU, medical devices containing natural rubber latex must be labelled as containing latex.
- CHEMOTHERAPY GLOVES
- Within the EU, these should be tested and certified to EN374. The FDA currently requires testing to publish the claim that any glove is appropriate for use with chemotherapy drugs. These are thicker (greater than 0.10 mm) latex and nitrile examination gloves.
- CHLORINATION
- Instead of powdering gloves, some manufacturers dip gloves into a chlorinated solution. This process reacts
with the natural rubber latex to reduce tackiness, thus eliminating the need for additional dusting powder. Extra washing during the chlorination process provides an added benefit by greatly reducing the level of soluble latex proteins. It also affects some cosmetic and physical glove characteristics (softness and colour).
- CLASS 1 - 100,000 CLEANROOMS
- Classification levels that indicate the acceptable number of particles in a cubic foot of cleanroom space. Class levels are generally determined from the number of 0.5 micron or larger particles per cubic foot.
- CLASS I MEDICAL DEVICE (EU)
- A device which is self-certified by the manufacturer and sold within the EU. These are generally lower risk products but are subject to certification if the device is either sterile or has a measuring function. Examination gloves are class I
unless they are sterile in which case, they are class Ia.
- CLASS I MEDICAL DEVICE (US)
- A device for which the controls authorized by or under sections of the Federal Food, Drug and Cosmetic act are sufficient to provide reasonable assurance of the safety and effectiveness of the device.
- CLASS II MEDICAL DEVICE (US)
- A device that cannot be classified as Class I device because the sections of the Federal Food, Drug and
Cosmetic Act by themselves are insufficient to provide reasonable assurance of the safety and effectiveness of the device for which there is sufficient information to establish special controls to provide such assurance, including the dissemination of guidelines. Medical Examination Gloves are considered Class II Devices.
- CLASS IIa MEDICAL DEVICE (EU)
- A surgically invasive device intended for short-term use, surgical gloves are class IIa.
- CLEANROOM
- A contained room in which contaminants such as dust is reduced to a very low level by special processes so that operations such as the manufacture and assembly of delicate equipment, manufacture and handling of pharmaceuticals or working with biological materials, can be performed effectively. Cleanroom gloves are widely found in the electronic and pharmaceutical laboratory industries. There are several clean room class types, the lower
the class number the cleaner the environment/less particulate allowed: Class 1 (M1.5), Class 10 (M2.5), Class 100 (M3.5), Class 1000 (M4.5) and Class 10000 (M5.5).
- CLEANROOM APPAREL/GARMENTS/CLOTHING
- Non-shedding apparel that is designed specifically to serve as a barrier between cleanroom environments and possible contaminants released by cleanroom workers. Cleanroom garments may include footwear, shoe covers, coveralls, gowns, smocks, gloves, face masks, and head coverings.
- CLEANROOM CLASSIFICATIONS
- Classification system used to determine the acceptable concentration of particles in an identified volume of air given specific particle size parameters. Classification levels are determined by the federal government.
- COMPOUNDING
- During the glove manufacturing process, chemicals are added, including accelerators (to help control the later vulcanization process) and antioxidants (to prevent deterioration of the rubber molecules in the final product by heat, moisture and ozone).
- CONTAINMENT
- The utilization of filters and controlled ventilation systems in a designated space for capturing and containing potential contaminants.
- CUFF
- The upper portion of a glove which encircles the wrist. Designs range from straight, rolled (beaded) or fluted. Gauntlet cuffs offer the benefits of a safety cuff, plus a flared design that fits over the garment sleeve of the wearer.
D
- DEGRADATION
- Damaging effects that liquid chemicals, extreme heat, ozone, fatigue or other substances have on the physical properties of the gloves. Signs of degradation may include softening and tackiness, brittleness, loss of elasticity, growth or ballooning at the finger tips.
- DERMATITIS
- A general term referring to any inflammation of the skin; may be caused by irritation or Type IV (delayed type) hypersensitivity. Characterized by erythema (redness), pain, pruritus (itching), vesicles (tiny blisters) and papules (hard bumps). If the dermatitis continues for a long period of time (becomes chronic), symptoms may expand to include drying, scaling, peeling and keratosis (thickening and hardening of the skin).
- DIPPING
- This is the process of submerging glove formers (moulds) into tanks containing a compound or a solution. The hand shaped formers are coated with a coagulant (e.g. calcium nitrate) and dipped into the latex to coat them with a thin film of latex. The coagulant converts the liquid latex into a wet gel on the former. Subsequent passage through a warm oven completes the coagulation process.
E
- ELECTROSTATIC DISCHARGE (ESD)
- The transfer of electric charge between two surfaces as a result of friction.
- ELONGATION
- The measurement of the length a glove that can be stretched before it breaks. It is expressed as a percent of the original length of the glove at the moment it breaks. The higher the percent, the more stretchable the glove material.
- EN455
- A series of standard for medical gloves covering freedom from holes, physical properties, biological evaluation and shelf life.
F
- FDA 510(k) Number
- Section 510(k) of the Food, Drug and Cosmetic Act requires that all device manufacturers must register to notify the FDA, at least 90 days in advance, of their intent to market any medical device. This is known as a Premarket notification, and allows the FDA to determine whether the device is equivalent to a device already placed into one of the three classification categories (Class I, II, III). Devices are awarded specific numbers for each product. Major product modifications may require a new 510(k) number. Search FDA releasable 510(k) database at http://www.fda.gov/cdrh/510khome.htm
G
- GAMMA IRRADIATION/STERILIZATION
- A popular method of sterilization utilized in the healthcare industry which uses electromagnetic radiation (bombardment of high energy photons and gamma rays) as opposed to chemicals such as Ethylene Oxide.
- GAUGE (THICKNESS)
- A glove thickness is measured in gauge, mil or millimetre. Low gauge (thin) gloves provide more flexibility and
sensitive touch, while higher gauge (thicker) gloves offer enhanced protection.
H
- HYPERSENSITIVITY
- This is a term used to describe a heightened response to a substance (I.e. an antigen), that has developed after
repeated exposure, and causes a genetically predisposed (atopic) individual to become sensitized or allergic (Type I or Type IV).
- HYPOALLERGENIC
- With regard to gloves, the claim hypoallergenic was developed to describe a reduced potential for developing a dermatological response to chemicals utilized in production of a given product. The 200-person modified Draize test is used to determine potential irritancy or allergic contact dermatitis (Type IV) to the product. After manufacturing product to meet these requirements, manufacturers could utilize the term hypoallergenic as an identifier for the product (a claim). However, in recent years individuals have also developed Type I allergic reactions in association
with the proteins from the gloves. Because the label claim of hypoallergenic was being interpreted as to refer to both Type IV and Type I allergies, rather than just Type IV, this claim was removed from all gloves on September 30, 1998
I
- ISO Cleanroom Classifications
- Cleanroom air cleanliness classifications that provide standards for the identification, control, and monitoring of various airborne particles and contaminants.
J
K
L
- LATEX
- Natural Rubber Latex is a milky sap-like substance produced by the rubber tree (Hevea Brasiliensis), found in Southeast Asia, India and South America. When the trunks of these rubber trees are tapped, they produce latex. This latex is then collected and used in manufacturing. Natural Rubber Latex is harvested from the rubber tree by a process of shallow cuts in the bark, called “tapping”. Latex coagulates on exposure to air, so the tapped liquid is “preserved” with ammonia. Then the solids are separated, like cream from milk. The Latex used for medical examination and surgical gloves is filtered and combined with selected chemical ingredients to enhance elasticity, strength, durability, and resistance to damage from ozone and other ageing effects.
- LATEX FREE
- Containing NO natural rubber latex (e.g. nitrile, vinyl, polychloroprene etc.).
- LEACHING
- The washing process, commonly used during the manufacturing of gloves, to remove or denature natural water-soluble proteins and remove adverse materials such as processing chemical residues. Water or wet gel leaching is the process of immersing the latex coated formers into a bath or spray of water, to wash out excess additives from previous stages, such as coagulant. Chemical and protein content is reduced at this stage. The effectiveness of the process is dependent on the temperature of the water, the duration of the process and the rate of water exchange. Dry Film leaching is similar to wet film leaching, except it is carried out on the dry/vulcanized latex film. The effectiveness of this process in reducing water extractives is a function of time and temperature.
- LENGTH
- Glove length is determined by the depth of hand/arm immersion in the solution and the extent of splash protection required. To protect the hand and wrist, select a glove 9-14” long (23-36cm). Elbow length, typically 14-18” (36-46 cm) protects the forearm. Shoulder length, about 31” (78cm) gives full arm protection.
M
- MAJOR DEFECTS
- A defect that may cause the product to fail, cause poor performance or shortened life of the unit (e.g. pinhole).
- MIL
- Measurement used for thickness of glove. Millimetres divided by 0.25=mil. One mill=0.001 inches=0.025mm
- MINOR DEFECT
- A cosmetic defect that is not likely to reduce materially the usability of the glove (e.g. discoloration).
- MODULAR CLEANROOM
- Versatile engineered and pre-fabricated cleanroom units that are fitted with self-contained ventilation and electrical systems that comply with industry standards. Modular cleanrooms can be designed to accommodate a variety of size and design constraints.
N
- NITRILE
- Nitrile gloves are made from a synthetic polymer composed of three monomers: acrylonitrile, butadiene and a carboxylic acid. The polymer properties are dependent on variations in composition. The term “nitrile” is used as a description because many of the distinguishing features of these polymers are due to the monomer acrylonitrile. The monomer imparts permeation resistance, allowing the material to withstand exposure to a wide variety of solvents and chemicals. It also determines the softness of the product and permits nitrile to be made with either a high or low modulus.
O
P
- PARTICLE COUNTER
- Device that measures the size and quantity of particles per cubic air volume. Used to determine the cleanliness rating of a cleanroom.
- PERMEATION
- The movement of a chemical through a glove on a molecular level. Data displaying permeation values represent breakthrough times when the glove is under continuous contact with the test chemical.
- PINHOLES
- Minute holes that may be present in glove film. They are often created by presence of debris (dust, dirt, etc.) during the manufacturing process.
- POLYMER COATING
- A synthetic material (compounded by polymerization and consisting of repeating structural units) applied to the inside of the glove during manufacturing to eliminate or reduce the need for donning powders such as corn-starch.
- POWDER
- Donning powder on gloves is composed of modified corn-starch (USP absorbable dusting powder). Powder facilitates donning and absorbs moisture. Studies have shown powder to function as abrasive particles, immunological activators, and possibly as vehicles for the dissemination of chemicals, proteins and microorganisms. Powder has been implicated in lowering of resistance to infection. It also has been shown to interfere with wound healing processes, increasing the risk for incremental complications in OR and post-operative care.
- PRIMARY SKIN IRRITATION TEST
- A test to determine if a certain material can cause skin irritation. The test material, such as a piece of
glove material, is attached to the skin of test subjects, such as rabbits or guinea pigs. After maintaining the skin contact for 24 hours, the contact area is observed for up to 72 hours for any kind of skin reactions.
Q
R
S
- STERILIZATION
- The use of a physical or chemical procedure to destroy all microbial life, including highly resistant bacterial spores.
- STRIPPING
- The manual or automated process of removing gloves from the formers, where the outside of the glove becomes the inside of the glove.
- SYNTHETIC RUBBER
- Manufactured and not of natural origin; produced by chemical synthesis. Synthetic gloves include, butane not limited to, neoprene (chloroprene), nitrile, polyisoprene and styrene butadiene (SBR).
T
- TACTILE SENSITIVITY
- The degree to which an object or substance can be discerned with sense of touch.
- TENSILE STRENGTH
- The measurement of the amount of stretch or pull required to rupture or break the glove material.
- TEXTURED
- The visual or tactile surface characteristics and appearance of something (e.g. a glove) represented by an uneven surface.
- TYPE I HYPERSENSITIVITY (PROTEIN ALLERGY)
- An lgE-mediated immediate hypersensitivity reaction, characterized by contact urticaria (hives), angioedema, rhinitis, respiratory complications, drop in blood pressure and rapid heart rate which may potentially progress to anaphylaxis. Severe cases can be fatal. Examples include Type I allergies to: penicillin, peanuts, strawberries, bee stings and natural rubber latex proteins.
- TYPE IV HYPERSENSITIVITY (CHEMICAL ALLERGY)
- A cell-mediated delayed hypersensitivity reaction, characterized by dermatitis, eczema, erythema, vesiculation (blisters), keratosis, hyperplasty (thickening of skin) and cracking. The area affected usually increases with repeated exposure. Examples include Type IV allergies to: poison oak, nickel, soaps and fragrances.
U
V
- VINYL GLOVES
- Usually referring to polyvinyl chloride (PVC) gloves. PVC is used as a latex substitute in many medical and industrial applications. Although the material itself is a barrier to most microorganisms, its non-elastic properties do not allow for maintenance of barrier integrity after extended use, or in rigorous procedures. Vinyl Gloves are sometimes known as “Synthetic Gloves”.
- VIRAL PENETRATION
- The ability of a virus to pass through a solid.
- VULCANISATION
- Vulcanisation was a key discovery in the manufacture of rubber products. Chemical agents such as sulphur are used to create strong chemical cross-links between the intertwined rubber polymers. This chemical transformation results in a network structure much stronger and more elastic than that of the initial (raw) material.
W
- WATER EXTRACTABLE PROTEINS
- The measurable amount of proteins, in terms of micrograms or milligrams, produced by water extraction on natural rubber latex gloves. ASTM D5712 provides an analytical test for determining the amount of total water extractable protein associated with natural rubber and its products. The test method involves an extraction and precipitation procedure followed by an assay of protein content (Modified Lowry Protein Assay).
- WATER LEAK TEST
- A test procedure recognized under EN455-1, ASTM D5151 and FDA protocols to determine the AQL level of an exam glove for pin holes. The latex glove is filled with a prescribed amount of water (1000ml) and must remain completely leak-proof over a defined period of time.
X
Y
Z